• Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
  • Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
  • Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
  • Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
  • Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
  • Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

After-sales Service: Long Time
Warranty: 1 Year
Element: Nitrogen
Analysis: Kjeldahl Method Protein Analysis
Display: Digital
Application: Grain, Feed, Food
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Trading Company
  • Overview
  • Product Description
  • Details Images
  • Related Product
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
NB9870
Frequency
50±1HZ
Performance
Automation
Function
Test,Analysis
Weight
0-100Kg
Power Source
AC220V±22V
Customized
Non-Customized
Name
Full Automatic Kjeldahl Nitrogen Analyzer
Measurement Time
4-8 Minutes
Power
1,800W
Power Supply
220V/50Hz
Cooling Water Consumption
1.5L/Min
Transport Package
Wooden Case
Specification
CE
Trademark
NANBEI
Origin
Zhengzhou, China
HS Code
9027809900
Production Capacity
1000 Pieces/Month

Product Description

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Product Description

 

NB9870 Full Automatic Kjedahl Nitrogen protein Analyzer

Operating system

Operating system has 7.5 inches large color touch display screen, SIEMENS CPU control platform, and can be connected to wireless mouse.

It has English display interface with perfect man-machine interaction function, and the operational process is easy to operate and understand

Two operating modes, automatic analysis and manual analysis, can meet requirements of different experiments.

USB data communication interface, standard configuration, is convenient for users to inquire raw data.

Wireless mouse, standard configuration.
Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Executive system

It adopts self-priming diaphragm pump imported with original packaging from British to feed liquid and thoroughly weeds out pneumatic diaphragm pump used by many domestic factories. Feeding liquid by self-priming pump can put liquid-feeding barrel under the operating floor which has advantages of effectively saving lab room, choosing large capacity liquid-feeding barrel, etc.

Control system

Main control system adopts advanced PLC control platform: the system control is reliable and accurate.

Intelligent cooling water automatic switching system: when there is steam, the cooling water turns on automatically; when there is no steam, the cooling water turns off automatically. It can save cooling water to maximum extent and avoid unwanted loss which is caused because operator forgets to turn off water source.

Pre-heat function: when it is in starting-up or ready mode, the temperature of steam cylinder always keeps 80ºC. When measure and analysis are needed, it can produce steam quickly which can shorten waiting time.

Automatic dilution function to avoid strong acid and alkali overreaction: before adding alkali, right amount of distilled water shall be added to dilute strong acid sample in order to avoid strong reaction when strong acid meets strong alkali.

Program of automatically washing titration cup: it can avoid non-neutral residual liquid influencing low-content or blank sample to improve system accuracy and reliability. 

Unique automatic discharge and centralized collection function of digestion tube waste: after the completion of titration, the digestion tube waste liquid will be discharged automatically and collected intensively. Automaticity is improved greatly, which reduces workers' labor intensity, solves the centralized collection and treatment of analysis liquid waste and complies with the management standards of good lab.

Automatic discharge and centralized collection of titration liquid waste: self-priming pump automatic titration liquid waste discharge device make the waste liquid in titration cup discharge more convenient and thorough and also make the pipeline connection more easy and practical because it has the same collection entrance with waste liquid of digestion tube. 

All pipelines of the instrument adopt imported materials and have sealed structure which could extent the service life of the instrument.

Automatic calibration system of titration liquid concentration (mol)

Dual mode of automatic calibration method which instrument eliminates errors and traditional direct input method

Automatic calibration method which instrument eliminates errors: this method eliminates system errors which are caused by the difference between the exterior calibration of instrument and the instrument titration (calibration) and makes the system precision higher.

Safety protection system

Digestion tube vacant protection: the system will not heat up if the digestion tube isn't put in;

Safety door vacant protection: if the safety door isn't pull down, the system will not heat up;

Automatic water-replenishing function of steam cylinder: when the steam generator has no water or its water level not high enough, the system will replenish water automatically to avoid burning without water;

Steam overpressure protection: when the pressure of steam generator system is too high because of the blocking and breakdown of steam pipeline or abnormal steam pipeline, the system will automatically stop running and give an alarm;

Leakage protection: when system has leakage of electricity or the operator gets an electric shock by accident, the system will switch off the electricity and cut off power supply to make sure the operator is safe.

Details Images

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
Operating system has 7.5 inches large color touch display screen, SIEMENS CPU control platform, and can be connected to wireless mouse.
USB data communication interface, standard configuration, is convenient for users to inquire raw data.

Wireless mouse, standard configuration 
Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer


Full Automatic Kjeldahl Distillation Unit Nitrogen AnalyzerDigestor,Waste gas collector,Neutralization unit are necessary equipment for kjeldahl analysis experiment. They need buy additional.

Technical indexes

NB9870

NB9870A

Working process

Adding quantitative sample dilution, alkali liquor and absorption liquid; automatically finishing distillation, titration, print and liquid-discharging. 

Measurement range

0.1-240mgN

Measurement time

4-8 minutes

Measurement sample amount

Solid: <6g/sample;liquid:<16ml./sample

Titration precision

2.0uL/step

0.5uL/step

Titrating solution concentration

Direct titration samples with four titration concentrations of 0.1 mol, 0.2 mol, 0.5 mol and 1 mol

Titration system

High-precision plunger type titration system

 

High-precision peristaltic titration system

Executive standard

Comply with stipulations of AOAC, EPA, DIN, ISO and GB

Repeatability precision

±0.5%

Recovery ratio

≥99.5%

Data storage

Effective storage space 2G

Print function

110mm line printer which can realize user selective print function

Power

1,800W

Power supply

220V/50Hz

Requirement of cooling water

Under 25ºC

Cooling water consumption

1.5L/min(Distillation process)

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Related Product

We also have Semi-automatic Kjedahl nitrogen analyzer,economical and cost-effective
Please click on the picture for more information
 

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer
Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Packaging & Shipping

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Company Profile

Full Automatic Kjeldahl Distillation Unit Nitrogen AnalyzerFull Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

Certifications

Full Automatic Kjeldahl Distillation Unit Nitrogen Analyzer

FAQ

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can we visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express .
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:

  1. Warranty : 1 year
  2. We supply free part for quality problem in warranty
  3. Long life technical support and service

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now